Attach the cassette to a calibrated bio pump.
Air o cell sampling procedure.
Recommended sampling procedures general.
The air o cell sampler is designed to operate at an optimal flow rate of 15 liters per minute lpm.
Calibrated pump and timer air o cell cassettes permanent marker.
Air enters the cassette the particles become impacted on the sampling substrate and the air.
The air o cell sampler is designed to operate at an optimal flow rate of 15 liters per minute.
Remove the seal from the top of the cassette and retain to reseal when sampling is complete.
Check the expiry date of the air o cell is current and remove the seal from the bottom of the cassette and retain to reseal when sampling is complete.
Daniel baxter is the owner of eaa and inventor of the air o cell the most widely used bioaerosol sampler in the country.
Set the desired run time for sampling.
3 attach the outlet round hole to the supplied tubing adapter available upon request or use standard pvc tubing for use with high volume pumps only.
Comprehensive expertise in laboratory testing field sampling design research and development failure analysis and can routinely provide expert witness support.
The air o cell sampler is designed to operate at an optimal fl ow rate of 15 liters per minute.
The air flow path through the air o cell cassette is illustrated below in figure 1.
The user can employ any sampling pump capable of a minimum fl ow rate of 15 lpm.
Microbiology sampling protocol for use with air o cell cassettes this is a general list of procedures to follow in order to ensure quality and accuracy of analysis.
The air flow path through the air o cell cassette is illustrated in figure 1.
The air o cell product line contains some of our bestselling products.
2 remove and retain tape seal covering air o cell inlet and outlet.
Recommended sampling procedures general.
The first choice of air quality professionals air o cell sampling cassettes provide a quick method of collecting particles from the air that can be tested for a wide range of viable and non viable aero allergens including pollen.
Recommended sampling procedures general.
The user can employ any sampling pump capable of a minimum flow rate of 15lpm.
The user can employ any sampling pump capable of a minimum flow rate of 15 lpm.
Sampling procedure 1 prior to sampling calibrate the pump to 15 liters per minute.
Please refer to the user manual of the cassette and or pump for a complete list of instructions.
It is also capable of operating in any vertical or horizontal orientation or.
The zefon air o cell is an impaction based air sampler used in microbial sampling procedures designed to pull air across a tacky sampling medium trapping any airborne particulates.
The air o celltm air sampling cassette is a sampling device designed for the rapid collection and analysis of a wide range of airborne aerosols.